Solar inverter repair in Melbourne: faults, warranty and replacement

We repair and replace solar inverters across Melbourne: fault-finding when an inverter shows an error code or stops producing, repairs to the isolators and wiring around it, and replacement inverters, including battery-ready hybrids. It is part of our solar repairs and servicing.

Solar Victoria expects a good-quality inverter to last at least 10 years. Many codes are grid events that clear by themselves; repeat insulation, leakage and arc faults need a licensed electrician. Out of warranty, we quote a repair against a new solar inverter.

Updated

Get a free quoteCall 0485 000 015

Get your quote

Every federal rebate your home qualifies for, applied before you see a price.

0485 000 015sales@solarinstallations-melbourne.com.au

Solar inverter not working? Safe first checks

Most inverter problems show up as a light, a code or a flat line in the app. These checks are look-only: they tell you whether to wait or to call an electrician, and none of them needs a cover opened.

  1. Check the app. Compare today’s output in iSolarCloud, Solar.web and AlphaESS app with a similar day, and look for error codes. If the app has stopped updating but the inverter looks normal, it has often dropped off your Wi-Fi. On a system with Victoria’s emergency backstop, exports are automatically reduced until it reconnects.
  2. Read the inverter’s display or light. Write down the code, the date and the time. On a Sungrow SH-RS, touch the light to page through the codes.
  3. Rule out the grid and the weather. In a blackout, an inverter disconnects from the grid by design; a Sungrow restarts about 60 seconds after the grid returns. At night, in heavy cloud or under shade, a low-power message is normal.
  4. Look at the switchboard. Find the breaker labelled for the solar or inverter. If it has tripped, don’t keep resetting it: a breaker that trips again points to a fault. Leave it off and call an electrician.
  5. Look at the inverter and its DC isolators. Without touching them, look for scorch marks, melted plastic or cracked cases. Energy Safe Victoria warns that ageing isolator cases can let moisture in, a fire risk.
What the light on a Sungrow SH-RS hybrid means. Source: Sungrow’s user manual, section 2.4, checked November 2026.
LightWhat it means
Blue, steadyRunning normally
Blue, flashingStandby or starting up, not feeding power in yet
RedA system fault: the code shows on the display or in the app
OffBoth the AC and DC sides are powered down (the AC side can still be live)

Smell burning or hear unusual noises? Energy Safe Victoria lists a burning smell and unusual noises as warning signs. Don’t touch the inverter. If it is safe to reach the switchboard, follow the shutdown procedure posted there, then keep clear and call a licensed electrician; if you see smoke or flames, call 000. Sungrow’s own label says not to touch live parts for 10 minutes after disconnecting, and that only qualified people may open an inverter.

DC isolator faults and recalls

Restarting an inverter: the makers’ own steps

A restart can clear a code that hasn’t cleared by itself. Use only the switches named on your shutdown procedure label, only in the maker’s order, and only when nothing looks or smells wrong. If the code comes back, leave the system off and call us.

Fronius (Primo, Symo and GEN24)

  1. Switch off the AC side first: the inverter’s circuit breaker or safety switch.
  2. Then switch off the DC side: the DC switch on the inverter.
  3. Wait about 30 seconds, until no light shows on the inverter.
  4. Switch the AC side back on, then the DC side.

Sungrow SH-RS, after a system fault code

  1. Switch off the AC breaker and the DC switch, and the battery switches if you have a battery.
  2. Wait 15 minutes.
  3. Switch the AC and DC switches back on in turn.

Sources: Fronius Australia’s GEN24 and Primo and Symo help pages, and Sungrow’s SH-RS user manual, section 10.1, checked November 2026.

Monitoring app offline?

What do common Sungrow and Fronius error codes mean?

Codes fall into three groups: grid events the inverter is required to ride out, low-sun messages that clear by themselves, and faults on the DC (panel) wiring that need an electrician. The tables give each maker’s own meaning for the codes owners see most, and what you can safely do.

Sungrow hybrid inverter codes (SH-RS)

Source: Sungrow SH-RS hybrid inverter user manuals (2025), section 10.1, and Sungrow Australia’s grid protection note, checked November 2026. “Electrician” marks codes whose fix is electrical work.
CodeFaultWhat it meansWhat you can do
2, 3, 14, 15Grid overvoltageThe grid voltage at your home went above the inverter’s protection limit, so it disconnected.Wait: it reconnects when the grid is back to normal. If it keeps happening, Sungrow’s advice is to have the voltage measured and raise it with your network operator. Only an installer should change the protection settings.
4, 5Grid undervoltageThe grid voltage dropped below the protection limit.Wait for it to reconnect. If it repeats, have the grid voltage and the AC cable checked.
8, 9Grid over or under frequencyThe grid frequency went outside the allowed range.Wait for it to reconnect. Repeated codes are a question for your network operator.
10Grid power outageThe inverter can’t see the grid: a blackout, or its AC circuit breaker is off.Check for a blackout in your street and look at whether the solar breaker in the switchboard has tripped. If the grid is on and the breaker is on, the next checks are on the AC cabling: call an electrician.
12
Electrician
Excess leakage currentCurrent is leaking to earth. Sungrow says poor sunlight or damp conditions can cause it.It usually clears once conditions improve. If it shows in fine, dry weather, the AC and DC cable insulation needs testing.
37Excessively high ambient temperatureThe inverter is too hot and has stopped until it cools.Look for blocked vents, no airflow around it, or direct sun on its case, and keep the area clear. If it persists, its position or fan needs checking.
39
Electrician
Low system insulation resistanceThe insulation between the panels’ DC wiring and earth tested low, for example because of a damaged cable.Wait for it to clear. Sungrow notes it can appear on rainy days only; if it repeats when the weather is fine, the strings and DC cables need testing.
88
Electrician
Electric arc faultAn electric arc was detected on the DC (panel) side.Don’t keep clearing it. Sungrow’s fix is to isolate the DC side and inspect the cables, terminals and fuses, which is work for a licensed electrician.
84, 514
Electrician
Meter or CT reversed, meter communicationThe energy meter that measures your grid import and export is wired the wrong way round, or has stopped talking to the inverter.The meter and its wiring sit in your switchboard, so this is a job for your installer or an electrician.
714, 716
Electrician
Battery communication or connectionThe inverter has lost contact with the battery, or the battery connection is wrong.Note the code and call us; battery cabling is electrical work.
7, 11, 16, 19–25, 36, 38 and othersSystem faultAn internal fault the inverter can often recover from by itself.Wait for it to recover first. If it doesn’t, use Sungrow’s restart steps once. If the code comes back, call us.

Grid codes are the inverter doing its job. Under the Australian standard AS/NZS 4777 it must disconnect when the grid’s voltage or frequency leaves set limits, and Sungrow notes that voltage often wanders out of range around midday or at the end of a long supply line. If a grid code shows most sunny days, Sungrow recommends asking your network operator to check the voltage at the local transformer.

Overvoltage that keeps coming back: voltage rise and who fixes it

Victoria’s Electricity Distribution Code of Practice sets 230 V as the standard voltage for homes, measured at the meter, and measures the networks against a band of 216 V to 253 V. Above that, your inverter steps in. Jemena, the network for Melbourne’s northern and north-western suburbs, expects inverters on the Australia A settings of AS/NZS 4777.2:2020: output is cut from full power at 253 V to 20% at 260 V, and the inverter disconnects if the 10-minute average passes 258 V or the voltage reaches 265 V. A GEN24 shows code 1112 while it is cutting output; a Sungrow that trips shows a grid overvoltage code (2, 3, 14 or 15).

  • The street. Sungrow notes grid voltage often wanders out of range around midday or at the end of a long supply line. That is the distributor’s to fix.
  • Your own cabling. Exported power raises the voltage along the cables from the inverter to the street. In Energy Safe Victoria’s sample exam for the licensed electrical inspectors who check solar installations, that rise, across the solar mains, any sub-mains and the consumer mains, must stay under 2%: 4.6 V on a 230 V supply. A long or undersized run is fixed with heavier cable, by an electrician.

Have an electrician measure the voltage at the meter and the rise in your cabling first. If the grid itself runs high, ask your distributor: under the code it must give you information on your quality of supply free, within 10 business days, may charge for a specific test, and refunds that fee and acts if the test shows it is out of line. Still unresolved? The Energy and Water Ombudsman Victoria takes supply-quality complaints for free, once you have tried to sort it out with the company. Never ask for the trip settings to be widened: Sungrow’s manual allows its protection settings to be changed only with the local network operator’s consent.

Fronius state codes (Primo, Symo and GEN24)

Source: Fronius Australia’s SnapINverter help page (Primo, Symo) and GEN24 help page, checked November 2026.
CodeInverterWhat it meansWhat you can do
107Primo, SymoNo AC grid detected. No stable grid. It also shows after a brief power failure.Look at whether the inverter’s circuit breaker in the switchboard is on. If it has tripped, or the code stays, call us.
306, 509Primo, SymoPV power low; no feed-in for 24 hours. Not enough power from the panels: night-time, or panels covered with dirt or leaves.If the panels are clear, look at the DC switch at the bottom of the inverter: Fronius says it should be at “I” (on). If it is off and you don’t know why, call us before switching it on.
475, 502
Electrician
Primo, SymoInsulation resistance too low. The inverter’s automatic test found low insulation on the DC side: a problem with the panels or their cabling, often only in rain.Fronius says to have the system checked by an installer.
240–243
Electrician
Primo, SymoArc detection. Arc detection has triggered. Fronius says a problem with the panels or a storm can cause it.Have the system checked by an electrician before relying on it.
1175GEN24Too little DC power for feed-in. Not enough sun: morning or evening, rain or fog, or heavy shade.Nothing: it clears by itself once the panels get enough light.
1112GEN24Mains voltage-dependent power reduction. The grid voltage is above the stored limit, so the inverter cuts its output.Fronius says no action is needed.
1001GEN24Insulation measurement. A routine test after 24 hours of feeding in. Feed-in pauses while it runs.Nothing: it restarts by itself.
1030GEN24Wired shutdown (WSD) triggered. An emergency stop switch was pressed, or another error shut the inverter down.Check Solar.web for other codes at the same time and whether an emergency stop was pressed. Otherwise, call your installer.

A code not listed here? Note it with the inverter’s model and send both when you book: the full tables run to hundreds of codes, and the same number can mean different things on different models.

Sungrow inverters

Fronius inverters

Should you repair or replace a solar inverter?

Three things decide it: whether the fault is in the inverter at all, whether it is still under the maker’s warranty, and how old it is. Opening an inverter isn’t routine repair work: Sungrow’s label says only qualified people may open and maintain one, and its warranty excludes unauthorised repairs. So while it is under warranty, a fault inside the inverter goes to the maker, which (in Sungrow’s terms) repairs it on site or at a Sungrow office, or supplies a new or refurbished replacement. The repairs an electrician makes are to the isolators, wiring and settings around it.

How a fault usually ends: repaired on site, claimed under warranty, or replaced.
The situationWhat happens
The fault is outside the inverter: a tripped breaker, a failed DC isolator, damaged cabling or lost Wi-FiThe cause is repaired and the inverter stays.
An inverter fault within the maker’s warrantyA warranty claim: the maker repairs or replaces it. Sungrow may supply a different size or model, and covers the repaired or replacement unit for the rest of the warranty or 12 months, whichever is longer.
An inverter fault after the warrantyWe quote a repair, where one is available for that model, against a new inverter.
An ageing inverter, and you want a batteryReplace it with a hybrid, or keep it and add a battery with its own inverter.

Inverter warranties by maker

Makers’ own warranty terms and datasheets, checked October 2026 (Sungrow, Fronius, Alpha ESS); Fronius registration from Fronius Australia, checked November 2026.
MakerInverter warranty
Sungrow10 years from installation in Australia (at most 11 years from manufacture)
Fronius5 years Fronius Warranty Plus as standard; free 10-year Warranty Plus cover by registering a new inverter on Fronius Solar.web
Alpha ESS10 years product warranty (Australian datasheet)

When an ageing inverter is worth replacing

Solar Victoria expects a good-quality inverter to last at least 10 years if it was installed properly, and suggests a warranty of at least 5 years. It lists what shortens an inverter’s life: heat and poor ventilation, high grid voltage and poor power quality, large electrical spikes, dust, pests such as mice and ants and lightning. An inverter past 10 years, out of warranty and showing a repeat fault is the point to weigh a repair against a replacement, especially if a battery is on your list.

Solar warranties explained

Upgrading the whole system

How much does a solar inverter replacement cost?

We don’t publish a list price: a replacement inverter is quoted after we assess it, together with the panels it has to suit, your switchboard and your network’s rules. You get a fixed price before any work starts, and nothing is replaced without your go-ahead.

Get an inverter replacement quote

What changes the price of a replacement inverter:

  • Size, to suit your panels. Without a battery, the inverter’s output must be at least 75% of the panels’ peak power under the SAA Technical Requirements (version 1.9, February 2026), and the panels must stay within the inverter maker’s limit.
  • Phase and your network’s limit. Victoria’s networks pre-approve up to 10 kW of inverter on a single phase home and 30 kW on three phase, counting battery inverters too. Single or three phase?
  • Hybrid or string. A hybrid runs a battery now or later; a string inverter is solar only.
  • Emergency backstop. Since 1 October 2024, a replacement on a Victorian system up to 200 kVA needs a compatible (CSIP-AUS certified) inverter on the CEC approved list and a reliable internet connection. Without internet, a lower export limit applies. The exception is a like-for-like replacement on a system approved before 1 October 2024.
  • Isolators and switchboard work. Old DC isolators or wiring may need replacing at the same time, and wiring repairs come with a Certificate of Electrical Safety, as Energy Safe Victoria advises.
  • No STC discount on a swap. When a new inverter goes in, the Clean Energy Regulator leaves the existing panels out of any new STC claim, so replacing only the inverter brings no STCs. A full replacement system with new panels and inverter, or an extension with new panels, can qualify.
  • A battery you already have. It has to suit the new inverter, so it can narrow the choice of brand.

Backstop sources: Solar Victoria’s installer guidance and industry Q&A, and the Victorian Government’s factsheet, checked November 2026.

Replacing an old inverter with a battery-ready hybrid

A failed or ageing string inverter is the natural point to fit a hybrid: one box that runs the panels now and a battery when you add one, without a second inverter. Each hybrid pairs with particular batteries, so choose the inverter with the battery in mind:

  • Sungrow SH-RS: Sungrow high-voltage batteries (80 to 460 V input).
  • Fronius GEN24: Fronius Reserva, BYD Battery-Box Premium HVS/HVM and LG RESU FLEX, per Fronius.
  • Alpha ESS SMILE-G3: Alpha ESS SMILE-G3 9.3 kWh modules, 1 to 4 in series (up to 37.2 kWh).

A new hybrid connected to your panels must be emergency backstop enabled and, as Jemena puts it, stay connected to the internet. When the battery goes in, the federal Cheaper Home Batteries Program also covers a battery added to existing solar. Among its conditions, it must be a new battery on the Clean Energy Council approved battery list, able to join a virtual power plant (VPP) if it is connected to the grid, and installed by a Solar Accreditation Australia (SAA) accredited installer with battery endorsement.

Inverter still working well? You don’t have to replace it to get a battery: an AC-coupled battery comes with its own inverter and sits beside the old one. Hybrids get recalled too, GoodWe’s EHB and GE-branded GEH models among them, so check any hybrid you already have against the recall list.

Battery and hybrid inverter recalls

AC vs DC coupled batteries

How the battery rebate works

Warranty claims when your installer has closed

The maker’s warranty doesn’t end with the installer’s business. Solar Victoria notes that under the Australian Consumer Law importers are responsible for manufacturers’ warranties, so the claim goes to the maker’s Australian office.

  1. Find the paperwork. Sungrow asks for proof of purchase: your invoice, receipt or commissioning report. Its warranty passes to a new owner, but the original proof is still needed.
  2. Record the fault. Photograph the inverter’s label (model and serial number) and note each code with its date.
  3. Use the maker’s claim route. For Sungrow, the owner or the installer can lodge Sungrow’s online warranty claim at service.sungrowpower.com.au, and Sungrow recommends finding a local electrician when the installer can’t attend. For Fronius, check the warranty certificate in Fronius Solar.web, under Product registration. For other makers, use the makers’ Australian contacts.
  4. Don’t replace it first. Sungrow can reject a claim when the inverter is replaced without its prior consent, and its warranty doesn’t cover travel or on-site installation costs, so ask what the electrician charges for the visit.

The warranty sits on top of your rights under the Australian Consumer Law: Sungrow’s own terms say its goods come with guarantees that cannot be excluded. Its warranty also excludes damage from insufficient ventilation, surges from the panels or the grid and lightning.

Send us the brand, model and error code, and we’ll tell you how the claim works for your inverter and what the maker needs from an electrician.

Ask about your inverter

Panel, inverter and battery warranties

Inverters we service

Three Sungrow inverters of different sizes, white and silver wall-mounted units with front display panels
Image: Sungrow

We service and repair Sungrow, Fronius and Alpha ESS inverters across Melbourne, and replace them with the model that suits your panels, your network and any battery plans.

  • Sungrow: SH-RS hybrid inverters; SH-T three phase hybrid inverters. Monitoring: iSolarCloud.
  • Fronius: Primo GEN24 and Symo GEN24 hybrid inverters; Primo string inverters. Monitoring: Solar.web.
  • Alpha ESS: SMILE-G3-S5 hybrid inverters. Monitoring: the AlphaESS app.

Another brand, or a system we didn’t install? Send a photo of the inverter’s label and the code when you book, and we’ll confirm whether we can repair it or quote the replacement.

Sungrow inverters

Fronius inverters

Solar inverters we install

Inverter repairs: your questions

How much does it cost to replace a solar inverter?

A replacement is quoted after we assess the system, because the price depends on the inverter’s size and brand, whether it is a hybrid, the panels it has to suit and any switchboard work. Since 1 October 2024, a new inverter in Victoria must also be emergency backstop enabled unless it is a like-for-like replacement on a system approved before 1 October 2024, and swapping only the inverter brings no STC discount. What changes the price

How do I reset my solar inverter?

Use only the maker’s restart steps and the switches named on your shutdown label, and never if you smell burning or see damage. Fronius: switch off the AC side, then the DC switch, wait about 30 seconds until no light shows, then turn AC and DC back on. Sungrow, for a system fault that doesn’t clear: AC, DC and any battery switches off, then AC and DC back on 15 minutes later. If the code returns, leave it off and call an electrician. The makers’ restart steps

Is it worth repairing an old solar inverter?

Solar Victoria expects a good-quality inverter to last at least 10 years. Within the maker’s warranty, a faulty inverter is repaired or replaced under that warranty. After it, compare the repair quote with a new inverter, which comes with a new warranty and can be a hybrid ready for a battery. Faults outside the inverter, such as a DC isolator, cabling or a tripped breaker, are fixed without replacing it. Repair or replace

Can a faulty inverter under warranty be swapped before the maker approves the claim?

Not if you want the claim to succeed. Sungrow, for example, can reject a claim when the inverter was replaced without its prior consent, and its warranty doesn’t cover travel or on-site installation costs. Lodge the claim first, with your invoice, receipt or commissioning report, the serial number from the inverter’s label and the error codes. If your installer has closed, Sungrow lets you lodge it online yourself. Making a warranty claim

Does a new solar inverter need an internet connection in Victoria?

In most cases, yes. Since 1 October 2024, new, upgraded and replacement solar systems up to 200 kVA must be emergency backstop enabled: a compatible inverter and a reliable internet connection, so the network can turn exports down in a rare grid emergency. Without internet, a lower export limit applies. Solar Victoria exempts a like-for-like replacement on a system approved before 1 October 2024.

Why does my inverter keep showing a grid voltage error?

Under the Australian standard AS/NZS 4777, an inverter must disconnect when the grid’s voltage or frequency leaves set limits. Sungrow says this is common around midday or for homes at the end of a long supply line, and the inverter restarts about 60 seconds after the grid is back to normal. If it happens often, Sungrow recommends asking your network operator to check the voltage. Voltage rise and who fixes it

Inverter repairs in Melbourne: the local rules

For a Melbourne home, three rules shape what a repair or replacement involves. Grid voltage is your distributor’s job (AusNet Services, CitiPower, Jemena, Powercor or United Energy), so once an electrician has ruled out your own cabling, the voltage check is asked of the network. A replacement must meet Victoria’s emergency backstop: since 1 October 2024 that means a compatible (CSIP-AUS certified) inverter on the CEC approved list and a reliable internet connection, unless it is a like-for-like replacement on a system approved before 1 October 2024. And swapping only the inverter earns no STCs, so there is no federal rebate to wait for. Before booking, photograph the inverter’s label and note the code with its date and time.

Book an inverter check with our Mount Waverley team

Book an inverter repair or replacement quote

Send us the inverter’s brand, model and error code. We find the fault first, and any replacement is quoted before work starts.

Get a free quoteOr call 0485 000 015

Talk to us about your inverter

Locally owned, locally installed. Call, email, or send the form and we’ll come out and inspect the property.

Workshop
8/41 Ricketts Road,
Mount Waverley, VIC 3149

Get a quote

We’ll get back to you about your quote.
No spam, no door knocking.